Material Properties: Platinum
 Data Available:
 Thermal Conductivity
 Specific Heat

 

 
Thermal Conductivity
Specific Heat
UNITS W/(m-K) J/(kg-K)
a -7.33450054 -1.6135538
b 80.8550484 0.95823584
c -268.441084 1.4317770
d 481.629105 -3.5963989
e -503.890454 5.1299735
f 314.812622 -2.4186452
g -115.699394 -0.12560841
h 23.0957119 0.34342394
i -1.93361717 -0.06198179
data range
3-298 1-296
equation range
4-295 1-295
curve fit % error relative to data 3 3
Curve fit equation of the form:
log10 y = a+b(log10T) + c(log10T) 2 + d(log10T) 3 + e(log10T) 4 + f(log10T) 5 + g(log10T) 6 + h(log10T) 7 + i(log10T) 8


Solves as:
y = 10
a+b(log10T) + c(log10T) 2 + d(log10T) 3 + e(log10T) 4 + f(log10T) 5 + g(log10T) 6 + h(log10T) 7 + i(log10T) 8

Where: Coefficients a - i are summarized in the appropriate table and T is the temperature in K (x-axis), and y is the property to solve for.